Signals
What a signal is, where signals come from, their states, how a signal opens an incident, and how to silence signals.
On this page
After you read this guide, you know what reaches Kosken as a signal, when a signal opens an incident, and how to stop signals during planned work.
What a signal is
A signal is one report that something is wrong, for example "disk of web-01 is 91% full". Open Signals in the sidebar to see them. The page has these tabs:
- Monitors: checks that the agent runs on your machines. See Monitors.
- Probes: checks of a public address from outside.
- Alert sources: alerts from your own tools. See Alert sources.
- Maintenance and silence windows: times when signals open no incident.
- Recent signals: the signals that arrived.
- Link rules: rules that link an alert to a machine. Only people with write access see this tab.
Every member can see the page. To add, edit or delete anything on it, you need write access.
Where signals come from


- Monitor
- The agent on the machine runs the check. The monitor fires after a number of failed checks in a row, 3 by default. A firing monitor clears after 2 passed checks in a row.
- Probe
- Kosken checks a public address from outside, with
http,tlsortcp. See Probes. - Alert
- A tool such as Alertmanager, Grafana or Datadog sends an alert to Kosken.
Each signal has a severity: Info, Warning or Critical.
States
- Firing: the problem is there now.
- Resolved: the problem ended. A monitor or a probe that passes again resolves its signal. An alert source sends a resolved alert.
- Silenced: a mark on a firing signal. A window covered it, or the monitoring of its machine is paused. A silenced signal opens no incident.
When the same problem fires again while its signal is still firing, Kosken updates that signal. It does not make a second one. The Fingerprint of the signal tells two problems apart.
How a signal opens an incident
A firing signal opens an incident when all of these are true:
- The signal belongs to a machine of the workspace that is not archived.
- No window silences it.
- Its severity is Warning or higher. A monitor can change this in its field Incident: Always open an incident, or Never: record the signal only.
A signal with no machine stays on the list and opens no incident. To give it a machine, add a link rule. When a window ends and a signal that it silenced is still firing, Kosken checks the signal again, and it can then open an incident. For what happens next, see Incidents.
Silence signals
Use a window for planned work. In the tab Maintenance and silence windows, click Add window.
- Choose the Type. Maintenance is planned work. Silence stops alerts with no plan.
- Type a Name, for example
Kernel upgrade. - In Machines, choose one machine, or keep All machines. A silence needs one machine.
- Set Starts and Ends, in UTC. A window lasts at most one year.
- In Repeat, choose None, Every day or Every week. A window that repeats must be shorter than its period.
- Click Save.
A delete of a window looks again at the signals that it silenced. To silence machines and also give the agent a plan, use a maintenance instead.
Link an alert to a machine
Kosken finds the machine of an alert from its labels and host name. See Alert sources. When it finds none, it tries the link rules. In the tab Link rules:
- Type a Label name, for example
service. - Type a Label value, for example
shop. - Choose the Machine, for example
web-01. - Click Add rule.
An alert whose labels have that name and value then belongs to web-01. The tab does not list the rules that exist.
Probes
A probe checks a public address from outside your network. In the tab Probes, click Add probe. Choose the Type: http asks for a page, tls reads the certificate, tcp opens a connection. Type the Target, a public address. The Interval (seconds) is 30 seconds or more. A probe fires after 2 failed runs in a row by default. A workspace has at most 20 probes.
A probe belongs to no machine. Its signal opens an incident only when a link rule gives it a machine. Each probe signal has the label probe with the name of the probe, so a link rule with the label name probe and the probe name as value links it.
The page of a signal
In Recent signals, click a signal to open it. The page shows:
- What fired: the type, the machine, the monitor, the incident and the fingerprint.
- When: the start, the last time it was seen, the resolve and the duration.
- Evidence: for a monitor, the Value when it fired and the lines that the agent sent, redacted on the machine. For an alert, the document that the source sent, redacted.
- Labels.
Open the incident opens the incident of the signal. Edit the monitor opens the monitor that fired.
Something here does not match the app? Tell us